ABO and RhD Blood Grouping & Typing Rapid Tests, Fast results ,Health Rapid Test
Principle | Solid-phase Method |
Format | Cassette |
Specimen | WB |
Reading Time | 1 minute |
Pack | 25 T |
Storage Temperature | 2-30°C |
Shelf Life | 2 Years |
Sensitivity | >99.9% |
Specificity | >99.9% |
Accuracy | >99.9% |
The ABO and RhD Blood Grouping Rapid Test Cassette (Whole Blood) is a solid-phase method test cassette for the regular ABO and RhD blood group detection. The test is intended for professional use to help diagnose the blood type.
SUMMARY
Human blood has a variety of blood types, and the most common blood type system is ABO (blood types are divided into A, B, AB and O types according to the presence or absence of A and B antigens in red blood cells).The second is the Rh blood system which divides blood groups into Rh positive and negative based on the presence or absence of D antigen on red blood cells.
When the corresponding antigens and antibodies of ABO and RhD blood group meet, red blood cells will have agglutination reaction, resulting in red blood cell hemolysis, which is life-threatening. Therefore, ABO and RhD blood group identification, or ABO and RhD blood group antigen test, is an important prerequisite for ensuring safe blood transfusion and avoiding related diseases.
The ABO and RhD Blood Grouping Rapid Test Cassette (Whole Blood) is a solid-phase method test cassette for the regular ABO and RhD blood group detection.
DIRECTIONS FOR USE
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing
1.Remove the test cassette from the sealed foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2.Place the cassette on a clean and level surface.
3.Hold the dropper vertically and transfer 1 drop of whole blood (approximately 10 mL) to each “S” well of test cassette. See illustration below.
4.Add 7-8 drops (approximately 500mL) of dilution buffer to “Buffer” well in 1 minute after the specimen is added.
5.Interpret test results in 1 minute on “S” well. Do not interpret the result after 30 minutes.
Note:If small amount of red blood cells remain in the “S” well was observed at reading time, please add 2-3 drops of dilution buffer to “Buffer” well and read the results immediately.
Note:It is suggested not to use the buffer, beyond 6 months after opening the vial.
INTERPRETATION OF RESULT
Monoclonal anti-A | Monoclonal anti-B | Monoclonal anti-RhD IgM | Results(Blood Phenotype) |
-(White) | -(White) | +(Red) | O and RhD+ |
+(Red) | -(White) | +(Red) | A and RhD+ |
-(White) | +(Red) | +(Red) | B and RhD+ |
+(Red) | +(Red) | +(Red) | AB and RhD+ |
-(White) | -(White) | -(White) | O and RhD- |
+(Red) | -(White) | -(White) | A and RhD- |
-(White) | +(Red) | -(White) | B and RhD- |
+(Red) | +(Red) | -(White) | AB and RhD- |
Order Information
Cat. No. | Product Description | Specimen | Format | Kit Size | Cut-Off |
OIBD-402 | ABO and RhD Blood Grouping & Typing Rapid Tests | WB | Cassette | 10 T | / |