Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
0.3-22 Ng/ML NT ProBNP Fluorescence Immunoassay Test Vitro Diagnostic

0.3-22 Ng/ML NT ProBNP Fluorescence Immunoassay Test Vitro Diagnostic

  • High Light

    NT ProBNP Fluorescence Immunoassay Test

    ,

    0.3ng/ML Fluorescence Immunoassay Test

    ,

    22 Ng/ML NT ProBNP Test Kit

  • Product
    CTnT Test Use By Fluorescence Immunoassay Analyzer In Human Whole Blood /serum /plasma
  • Cat. No.
    FI-NBNP-402
  • Principle
    Fluorescence Immunoassay
  • Format
    Cassette
  • Specimen
    WB/S/P
  • Certificate
    CE
  • Reading Time
    15 Minutes
  • Pack
    10T/25T
  • Storage Temperature
    4-30℃
  • Shelf Life
    2 Years
  • Linearity Range
    0.3~22 Ng/mL, R≥0.990
  • Cut-Off
    450 Pg/mL
  • Precision
    C.V. ≤15%
  • Accuracy
    The Test Deviation Is≤±15%
  • Analytical Sensitivity
    As Low As 0.2ng/mL Whole Blood, Serum Or Plasma
  • Detection Range
    0.3~22 Ng/mL
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    FI-NBNP-402
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    10T/25T
  • Delivery Time
    2-4 Weeks
  • Supply Ability
    10 M tests/month

0.3-22 Ng/ML NT ProBNP Fluorescence Immunoassay Test Vitro Diagnostic

Product features Parameters
Principle Fluorescence Immunoassay
Format Cassette
Specimen WB/S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Shelf Life 2 Years
Cut-Off 450 pg/mL

 

 

【PERFORMANCE CHARACTERISTICS】

1. Accuracy

The test deviation is ≤±15%.

2. Sensitivity

The NT-proBNP Test Cassette can detect levels of NTproBNP as low as 0.3 ng/mL in whole blood, serum or plasma.

3. Detection range

0.3~22 ng/mL

4. Linearity range

0.3~22 ng/mL, R≥0.990

5. Precision

C.V. ≤15%

 

 

 

Fast Result (15 minutes)

Simple Operation (Less Training Required)

Objective (Results Read by Analyzer)

Stringent Quality Control Insure High Accuracy

User-friendly (Simple Plug & Play Operation)

High Efficiency (Both STAT Testing and Batch Testing)

 

 

 

A test for measuringInfluenza NT-proBNP in whole blood /serum /plasma with the use of Citest TM Go fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.

 

Application:

 

The NT-proBNP Test Cassette (Whole Blood/Serum/Plasma) is intended for in vitro quantitative determination of human NT-proBNP in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).

 

Description:

 

The N-terminal of the prohormone brain natriuretic peptide (NT-proBNP) is a 76 amino acid N-terminal inactive protein that is cleaved from proBNP to release brain natriuretic peptide.Both BNP and NT-proBNP levels in the blood are used for screening, diagnosis of acute congestive heart failure (CHF) and may be useful to establish prognosis in heart failure, as both markers are typically higher in patients with worse outcome.

 

The plasma concentrations of both BNP and NT-proBNP are also typically increased in patients with asymptomatic or symptomatic left ventricular dysfunction and is associated with coronary artery disease and myocardial ischemia.[2][3][4]The NT-pro BNP Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of anti-NT-proBNP antibody coated particles and capture reagents to quantitatively detect NT-pro BNP in whole blood, serum or plasma. The minimum detection level is 0.3 ng/mL.

 

How to use?

 

Refer to Citest TM Go Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted in room temperature.

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

 

1. Turn on the Analyzer power. Then according to the need, select “Standard Test” or “Quick Test” mode.

2. Take out the ID card and insert it into the Analyzer ID Card Slot.

3. Pipette 50μL whole blood/serum/plasma into the buffer tube; mix the specimen and the buffer well.

4. Add diluted specimen with a Pipette: Pipette 85μL diluted specimen into the sample well of the test cassette. Start the timer at the same time.

5. There are two test modes for Citest TM Go Fluorescence Immunoassay Analyzer,Standard Test mode and Quick Test mode.

 

Please refer to the user manual of Citest TM Go Fluorescence Immunoassay Analyzer for details.

“Quick Test” mode: After 15 minutes of adding sample, Insert the test cassette into the Analyzer, click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

“Standard Test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time, The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.

 0.3-22 Ng/ML NT ProBNP Fluorescence Immunoassay Test Vitro Diagnostic 0

 

INTERPRETATION OF RESULTS


Results read by CitestTM Fluorescence Immunoassay Analyzer.


The result of tests for NT-proBNP is calculated by CitestTM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Citest TM Go Fluorescence Immunoassay Analyze.
Linearity range of CitestTM NT-proBNP Test is 0.3-22ng/ml.

 

Order Information

 

Catalogue Number Item Name Sample Test Range KIT size
FI-NBNP-402 NT-proBNP Test Cassette WB/S/P 18-35000 pg/mL 10T/25T