Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
SARS-CoV-2 COVID-19 Antigen Rapid Test Nasopharyngeal Swab / Nasal Swab

SARS-CoV-2 COVID-19 Antigen Rapid Test Nasopharyngeal Swab / Nasal Swab

  • High Light

    Nasopharyngeal Swab COVID 19 Antigen Rapid Test

    ,

    Nasal Swab COVID 19 Antigen Rapid Test

  • Product
    COVID-19 Antigen Rapid Test (Swab), Nasopharyngeal Swab/Nasal Swab, SARS-CoV-2 Antigen
  • Brand
    Citest
  • Cat NO.
    ICOV-502/INCP-502
  • Principle
    Chromatographic Immunoassay
  • Format
    Cassette
  • Specimen
    Oral Fluid/Nasopharyngeal Swab/Nasal Swab
  • Reading Time
    15 Minutes
  • Pack
    20T
  • Storage Temperature
    2-30°C
  • Shelf Life
    2 Years
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    ICOV-502/INCP-502
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    20T
  • Delivery Time
    2-4 Weeks
  • Payment Terms
    L/C, T/T
  • Supply Ability
    10 M tests/month

SARS-CoV-2 COVID-19 Antigen Rapid Test Nasopharyngeal Swab / Nasal Swab

COVID-19 Antigen Rapid Test (Swab), Nasopharyngeal Swab/Nasal Swab, SARS-CoV-2 Antigen

 

Product features Parameters
Principle Chromatographic Immunoassay
Format Cassette
Specimen Oral fluid/Nasopharyngeal Swab/Nasal Swab
Certificate CE
Reading Time 15 minutes
Pack 20 T
Storage Temperature 2-30°C
Shelf Life

2 Years

 

 

 

COVID-19 Antigen Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of SARS-CoV-2 Nucleocapsid Protein antigens in swab specimen. For professional in vitro diagnostic use only.
 
INTENDED USE
 
The COVID-19 Antigen Rapid Test (Swab) is a rapid chromatographic immunoassay for the qualitative detection of SARS-CoV-2 Nucleocapsid Protein antigens in swab specimens from individuals with suspected SARS-CoV-2 infection in conjunction with
clinical presentation and the results of other laboratory tests.
 
Results are for the detection of SARS-CoV-2 Antigens. An antigen is generally detectable in upper respiratory specimens during the acute phase of infection. Positive results indicate the presence of viral antigens, but clinical correlation with patient history
and other diagnostic information is necessary to determine infection status. Positive results do not rule out bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease.
 
Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions. Negative results should be treated as presumptive and confirmed with a molecular assay, if necessary for patient management. Negative results should be considered in the context of a patient’s recent exposures, history and the presence of clinical signs and symptoms consistent with COVID-19.
 
SUMMARY
 
The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are found in a few cases.
 
PRINCIPLE
 
The COVID-19 Antigen Rapid Test (Swab) is a qualitative membrane-based immunoassay for the detection of SARS-CoV-2 Antigens in human swab specimen. SARS-CoV-2 antibody is coated in the test line region. During testing, the specimen reacts with SARS-CoV-2 antibody-coated particles in the test. The mixture then migrates upward on the membrane by capillary action and reacts with the SARS-CoV-2 antibody in test line region. If the specimen contains SARS-CoV-2 Antigens, a colored line will appear in test line region as a result of this. If the specimen does not contain antigens to SARS-CoV-2, no colored line will appear in the test line region, indicating a negative result. To serve as a procedural control, a colored line will always appear in
the control line region, indicating that the proper volume of specimen has been added and membrane wicking has occurred.
 
STORAGE AND STABILITY
 
Store as packaged in the sealed pouch at room temperature or refrigerated (2-30°C). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.
 
SPECIMEN COLLECTION, TRANSPORT AND STORAGE
 
Nasopharyngeal Swab Specimen Collection
1. Insert a sterile swab into the nostril of the patient, reaching the surface of the posterior nasopharynx.
2. Swab over the surface of the posterior nasopharynx.
3. Withdraw the sterile swab from the nasal cavity.
SARS-CoV-2 COVID-19 Antigen Rapid Test Nasopharyngeal Swab / Nasal Swab 0
Nasal Swab Specimen Collection
 
1. Insert a sterile swab less than one inch (about 2 cm) into a nostril (until resistance is met at the turbinates).
2. Rotate the swab 5-10 times against the nasal wall. Using the same swab repeat the collection procedure with the second nostril.
3. Withdraw the sterile swab, avoid excess volume and high-viscous nasal discharge.
 
SARS-CoV-2 COVID-19 Antigen Rapid Test Nasopharyngeal Swab / Nasal Swab 1
 
Caution:
If the swab stick breaks during specimen collection, repeat specimen collection with a new swab.
Specimen transport and storage
Specimens should be tested as soon as possible after collection. If swabs are not been processed immediately, it is highly recommended the swab sample is placed into a dry, sterile, and tightly sealed plastic tube for storage. The swab specimen in dry and sterile condition is stable for up to 24 hours at 2-8°C.
 
SPECIMEN PREPARATION
 
Only the extraction buffer and tubes provided in the kit is to be used for swab specimen preparation.
Please refer to the Procedure card for detailed information of Specimen Extraction.
1.Place the swab specimen in the Extraction tube with Extraction Buffer. Rotate the swab for approximately 10 seconds while pressing the head against the inside of the tube to release the antigen in the swab.
2. Remove the swab while squeezing the swab head against the inside of the Extraction tube as you remove it to expel as much liquid as possible from the swab. Discard the swab in accordance with your biohazard waste disposal protocol.
*NOTE: The storage of the specimen after extraction is stable for 2 hours at room temperature or 24 hours at 2-8°C.
 
INTERPRETATION OF RESULTS
 
(Please refer to the illustration above)
 
POSITIVE:* Two distinct colored lines appear. One colored line should be in the control region (C) and another colored line should be in the Test region (T). Positive result in the Test region indicates detection of SARS-CoV-2 antigens in the sample.
*NOTE: The intensity of the color in the test line region (T) will vary based on the amount of SARS-CoV-2 antigen present in the sample. So any shade of color in the test region (T) should be considered positive.
 
NEGATIVE: One colored line appears in the control region (C). No apparent colored line appears in the test line region (T).
 
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Order Information

 

Cat. No. Product Specimen Pack
ICOV-502 COVID-19 Antigen Rapid Test Nasopharyngeal Swab 25T
INCP-502 SARS-CoV-2 Antigen Rapid Test Nasopharyngeal Swab/Nasal Swab 20T
ICOV-802 COVID-19 Antigen Rapid Test Oral Fluid 20T
INCP-502-N COVID-19 Antigen Rapid Test Nasal Swab 20T