Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
SP10 Sperm Motility One Step Rapid Screening Test 98.2% Accuracy

SP10 Sperm Motility One Step Rapid Screening Test 98.2% Accuracy

  • High Light

    Sperm Motility Rapid Screening Test

    ,

    rapid screening test 98.2% Accuracy

    ,

    SP10 sperm motility test

  • Product
    Ferritin Semi Quantitative Rapid Test Cassette In Whole Blood / Serum / Plasma
  • Cat. No.
    CE/CE0123
  • Principle
    Chromatographic Immunoassay
  • Format
    Cassette
  • Specimen
    WB/S/P
  • Certificate
    CE/CE0123
  • Reading Time
    5 Minutes
  • Pack
    1 T/2 T
  • Storage Temperature
    2-30°C
  • Shelf Life
    2 Years
  • Sensitivity
    98.1%
  • Specificity
    98.3%
  • Accuracy
    98.2%
  • Cut-Off
    15 Million/mL
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE/CE0123
  • Model Number
    OSP-902/OSP-902H
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    1 T/2 T
  • Delivery Time
    2-4 Weeks
  • Supply Ability
    10 M tests/month

SP10 Sperm Motility One Step Rapid Screening Test 98.2% Accuracy

SP-10 Male Fertility rapid with CE certified, one step screening test for detecting sperm motility according the concentration of sperm

 
Principle Chromatographic Immunoassay
Format Cassette
Specimen Sperm
Certificate CE/CE0123
Reading Time 5 minutes
Pack 1 T/2 T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 98.10%
Specificity 98.30%
Accuracy 98.20%
Cut-Off 15 million/mL

 

Applications:

 

The SP-10 Male Fertility Rapid Test Cassette is a rapid chromatographic immunoassay for in vitro qualitative detection of Acrosomal Protein SP-10 found on sperms to estimate of sperm concentration in human semen above or below 15 million / mL.

 

Description:

 

Two-thirds of all adults drink alcohol.¹ The blood alcohol concentration at which a person becomes impaired is variable dependent upon the individual. Each individual has specific parameters that affect the level of impairment such as size, weight, eating habits and alcohol tolerance. Inappropriate consumption of alcohol can be a contributing factor to many accidents, injuries, and medical conditions.

 

SP10 Sperm Motility One Step Rapid Screening Test 98.2% Accuracy 0

 

How to use?

 

Before testing, read the instructions completely carefully and completely


1. Remove the test cassette from the foil pouch and lay it horizontally on a flat surface.


2. A semen sample should be collected in the collection cup provided.


3. The sample should then be allowed to stand for 60 minutes , until the semen is fully liquefied.


4. Using the semen transfer device provided, fill the Semen transfer device up to 0.1 Ml indicated on the device with the semen sample. The semen sample is then added to the tube of sample dilution buffer provided.


5. Mix the semen sample and sample dilution buffer by turning the tube upside down 5-10 times .


6. Hold the diluted specimen buffer tube upright and open the cap onto the specimen collection tube. Invert the diluted specimen buffer tube and transfer 2 full drops of the diluted specimen (approximately 80 μL) to the specimen well (S) of the test cassette, then start the timer. Avoid trapping air bubbles in the specimen well (S). See illustration below.


7. Read results at 5 minutes after dispensing the specimen. Do not read results after 10 minutes.

 

SP10 Sperm Motility One Step Rapid Screening Test 98.2% Accuracy 1

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)


NORMAL:* Two colored lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).


*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of SP-10 protein present in the specimen. Therefore, any shade of color in the test line region (T) should be considered normal.


ABNORMAL: One colored line appears in the control line region (C). No line appears in the test line region (T).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

ORDER INFORMATION

 

 

Cat. No. Product Specimen Pack
OSP-902 SP-10 Male Fertility Rapid Test Cassette Sperm 1 T/2 T
OSP-902H SP-10 Male Fertility Rapid Test Cassette (Self-Testing) Sperm 1 T/2 T