Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity

  • High Light

    Citest EDDP Drug Test

    ,

    Drug Test 99.4% Specificity

    ,

    CE Ethylenediamine Dimethylphosphinic Acid EDDP Test

  • Product
    Ethylenediamine-dimethylphosphinic Acid (EDDP) Rapid Test,utilizes A Monoclonal Antibody
  • Cat. No.
    DED-102/114/101,DED-402
  • Principle
    Chromatographic Immunoassay
  • Format
    Dipstick, Cassette, Panel, Cup
  • Specimen
    Urine, WB/S/P
  • Certificate
    CE
  • Reading Time
    5 Minutes
  • Pack
    40T/50T
  • Storage Temperature
    2-30°C
  • Shelf Life
    2 Years
  • Sensitivity
    97.9%
  • Specificity
    99.4%
  • Accuracy
    98.8%
  • Cut-Off
    300 Ng/mL*, 100 Ng/mL, 50 Ng/mL
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    DED-102/114/101,DED-402
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    40/50T
  • Delivery Time
    2-4 Weeks
  • Supply Ability
    10 M tests/month

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine, WB/S/P
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.90%
Specificity 99.40%
Accuracy 98.80%
Cut-Off 300 ng/mL*, 100 ng/mL, 50 ng/mL

 

300ng Rapid test for the qualitative detection of EDDP in human urine​

 

Applications:

 

The EDDP (Methad/one Metabolite) Rapid Test Cassette (Urine) is a rapid immunochromatographic assay for the qualitative detection of 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), an inactive metabolite of meth/adone that acts as a narcotic pain reliever and is used as a treatment for opiate addiction.

 

This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity 0

 

Description:

 

Methad/one is an unusual drug in that its primary urinary metabolites (EDDP and EMDP) are cyclic in structure, making them very difficult to detect using immunoassays targeted to the native compound.1 Exacerbating this problem, there is a subsection of the population classified as “extensive metabolizers” of metha/done. In these individuals, a urine specimen may not contain enough parent metha/done to yield a positive drug screen even if the individual is in compliance with their metha/done maintenance. EDDP represents a better urine marker for metha/done maintenance than unmetabolized metha/done.

 

 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity 1

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity 2

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Ethylenediamine Dimethylphosphinic Acid EDDP Drug Test 99.4% Specificity 3

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Ethylenediamine-dimethylphosphinic acid (EDDP) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Ethylenediamine-dimethylphosphinic acid (EDDP) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Order Information
 

Cat. No. Product Specimen Pack
DED-102 Ethylenediamine-dimethylphosphinic acid (EDDP) Rapid Test Cassette Urine 40 T
DED-114 Ethylenediamine-dimethylphosphinic acid (EDDP) Rapid Test Panel Urine 40 T
DED-101 Ethylenediamine-dimethylphosphinic acid (EDDP) Rapid Test Dipstick Urine 50 T
DED-402 Ethylenediamine-dimethylphosphinic acid (EDDP) Rapid Test Cassette WB/S/P 40 T