Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
10-200ng/ML Norfen/tanyl FYL Fen/tanyl Rapid Test Monoclonal Antibody Kit

10-200ng/ML Norfen/tanyl FYL Fen/tanyl Rapid Test Monoclonal Antibody Kit

  • High Light

    Norfentanyl FYL Fentanyl Rapid Tes

    ,

    10ng/ML monoclonal antibody kit

    ,

    200ng/ML Fentanyl Rapid Test

  • Product
    Fen/tanyl (FYL) Rapid Test, Utilizes A Monoclonal Antibody,detect Elevated Levels Of Norfen/tanyl
  • Cat. No.
    DFY-102/101/114,DFY-802/803/402,DFY-X14
  • Principle
    Chromatographic Immunoassay
  • Format
    Dipstick, Cassette, Panel, Device, Cup
  • Specimen
    Urine,Oral Fluid,Powder,WB/S/P
  • Certificate
    CE
  • Reading Time
    5 Minutes
  • Pack
    25T/40T/50T
  • Storage Temperature
    2-30℃
  • Sensitivity
    98.8%
  • Specificity
    99.4%
  • Accuracy
    99.2%
  • Cut-Off
    10 Ng/mL,15 Ng/mL ,20 Ng/mL*,50 Ng/ml* ,100 Ng/mL ,200 Ng/mL
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    DFY-102/101/114,DFY-802/803/402,DFY-X14
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    25T/40T/50T
  • Delivery Time
    2-4 Weeks
  • Supply Ability
    10 M tests/month

10-200ng/ML Norfen/tanyl FYL Fen/tanyl Rapid Test Monoclonal Antibody Kit


 

 

Fen/tanyl (FYL) Rapid Test, utilizes a monoclonal antibody,detect elevated levels of Norfent/anyl

 

CE Oral Fluid Fen/tanyl (FYL) ​Convenient High Sensitivity Accurate Drug Abuse Diagnosis Fast Reading Test Kits

 

Application And Description:

 

Fen/tanyl, belongs to powerful narcotics analgesics, and is a special opiates receptor stimulant. Fe/ntanyl is one of the varieties that been listed in management of United Nations “Single Convention of narcotic drug in 1961”. Among the opiates agents that under international control, fen/tanyl is one of the most commonly used to cure moderate to severe pain. After continuous injection of fen/tanyl, the sufferer will have the performance of protracted opioid abstinence syndrome, such as ataxia and irritability etc, which presents the addiction after taking fen/tanyl in a long time.
 
Compared with drug addicts of amphe/tamine, drug addicts who take fen/tanyl mainly have got the possibility of higher infection rate of HIV, more dangerous injection behavior and more lifelong medication overdose.

 

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Device, Cup
Specimen Urine,Oral Fluid,Powder,WB/S/P
Certificate CE
Reading Time 5 minutes
Pack 25T/40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 98.80%
Specificity 99.40%
Accuracy 99.20%
Cut-Off 10 ng/mL,15 ng/mL ,20 ng/mL*,50 ng/ml* ,100 ng/mL ,200 ng/mL

 

 

How to use?

 

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.

2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.

3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the collection tube.

4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.

5. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 1 hour.

6. Apply the security seal over screw cap and send to the laboratory for confirmation if necessary.

10-200ng/ML Norfen/tanyl FYL Fen/tanyl Rapid Test Monoclonal Antibody Kit 0

 
DIRECTIONS FOR DEVICE USE
 
Allow the test device, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
 
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it within one hour.
 
2. Insert the absorbent wick to the mouth and put it under the tongue to collect oral fluid until the control line appears.
 
3. Place the test device on a clean and level surface. See illustration below.
 
4. Read results at 10 minutes. Do not read results after 15 minutes.

10-200ng/ML Norfen/tanyl FYL Fen/tanyl Rapid Test Monoclonal Antibody Kit 1

 

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). A negative result indicates that the Synthetic Marijuana metabolite concentration is below the detectable level (25ng/mL).


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). A positive result indicates that the Fen/tanyl (FYL) concentration exceeds the detectable level (50 ng/mL/20ng/ml).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 
Order Information
 
Cat. No. Product Specimen Pack
DFY-102 Fen/tanyl (FYL) Rapid Test Cassette Urine 40 T
DFY-114 Fen/tanyl (FYL) Rapid Test Panel Urine 40 T
DFY-101 Fen/tanyl (FYL) Rapid Test Dipstick Urine 50 T
DFY-802 Fen/tanyl (FYL) Rapid Test Cassette Oral Fluid 25 T
DFY-803 Fen/tanyl (FYL) Rapid Test Device Oral Fluid 25 T
DFY-402 Fen/tanyl (FYL) Rapid Test Cassette WB/S/P 40 T
DFY-X14 Fen/tanyl (FYL) Rapid Test Panel Powder 25 T