Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate

2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate

  • High Light

    Citest GAB Drug Abuse Test Kit

    ,

    Gabapentin Drug Abuse Test Kit

    ,

    2000ng/ML Gabapentin drug test

  • Product
    2000 Ng/mL Gabapentin GAB Drug Abuse Test Kit , One Step Rapid Test High Accurate
  • Cat. No.
    DGAB-102/114/101
  • Principle
    Chromatographic Immunoassay
  • Format
    Dipstick, Cassette, Panel, Cup
  • Specimen
    Urine
  • Certificate
    CE
  • Reading Time
    5 Minutes
  • Pack
    40T/50T
  • Storage Temperature
    2-30℃
  • Sensitivity
    92.3%
  • Specificity
    98.5%
  • Accuracy
    96.7%
  • Cut-Off
    2000 Ng/mL
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    DGAB-102/114/101
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    40T/50T
  • Delivery Time
    2-4 Weeks
  • Supply Ability
    10 M tests/month

2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate

2000 ng/mL Gabapentin GAB Drug Abuse Test Kit , One Step Rapid Test High Accurate

 

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 92.30%
Specificity 98.50%
Accuracy 96.70%
Cut-Off 2000 ng/mL


Applications And Description: 
 
Gabapentin, sold under the brand name Neurontin among others, is a medication which is used to treat epilepsy (specifically partial seizures), neuropathic pain, hot flashes, and restless legs syndrome. Common side effects of gabapentin include sleepiness and dizziness. Serious side effects include an increased risk of suicide, aggressive behavior, and drug reaction with eosinophilia and systemic symptoms.1 In 2009 the U.S.

 

Food and Drug Administration issued a warning of an increased risk of suicidal thoughts and behaviors in patients taking some anticonvulsant drugs, including gabapentin, modifying the packaging inserts to reflect this.

 
How to use? 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.

2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.

3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate 0

 

DIRECTIONS FOR PANEL USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.


1. Remove the test panel form the sealed pouch and use it as soon as possible.


2. Remove the cap.


3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.


4. Replace the cap and place the test panel on a non-absorbent flat surface.


5. Start the timer and wait for the colored line(s) to appear.


6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate 1

 

DIRECTIONS FOR DIPSTICK USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.


1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.


2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.


3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

2000ng/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate 2

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that theGabapentin(GAB) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Gabapentin(GAB) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Order Information

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DGAB-102 Gabapentin(GAB) Rapid Test Cassette Urine Cassette 40 T 2000 ng/mL CE
DGAB-114 Gabapentin(GAB) Rapid Test Panel Urine Panel 40 T CE
DGAB-101 Gabapentin(GAB) Rapid Test Dipstick Urine Dipstick 50 T CE