logo
Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
Barbiturates BAR Rapid Test Cassette Urine 200ng/ml GC / MS

Barbiturates BAR Rapid Test Cassette Urine 200ng/ml GC / MS

  • High Light

    BAR Rapid Test Cassette

    ,

    Drug Abuse Test Kit 200ng/ml

    ,

    200ng/ml Barbiturates Test Kit

  • Product
    BAR Rapid Test Cassette (Urine), 200ng/ml, Barbiturates Test Kit (GC/MS)
  • Cat No.
    DBA-102
  • Principle
    Chromatographic Immunoassay
  • Format
    Dipstick, Cassette, Panel, Device, Cup
  • Specimen
    Urine
  • Certificate
    CE/FDA
  • Reading Time
    5 Minutes
  • Pack
    25T/40T/50T
  • Sensitivity
    96.1%
  • Specificity
    98.6%
  • Accuracy
    97.6%
  • Cut-Off
    100 Ng/mL,200 Ng/mL,
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE/FDA
  • Model Number
    DBA-102
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    25T/40T/50T
  • Delivery Time
    2-4 Weeks

Barbiturates BAR Rapid Test Cassette Urine 200ng/ml GC / MS

 

BAR Rapid Test Cassette (Urine), 200ng/ml, Barbiturates Test Kit (GC/MS)

 

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Device, Cup
Specimen Urine,Oral Fluid,Powder,WB/S/P,Hair
Certificate CE/FDA
Reading Time 5 minutes
Pack 10T/25T/40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 96.10%
Specificity 98.60%
Accuracy 97.60%
Cut-Off 100 ng/mL,200 ng/mL,

 

 

 

A rapid test for the qualitative detection of Barbiturates in human urine.
For medical and other professional in vitro diagnostic use only.
 
INTENDED USE
 
The BAR Rapid Test Cassette (Urine) is a lateral flow chromatographic immunoassay for the detection of Barbiturates in urine at a cut-off concentration of 200ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.
 
This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result,particularly when preliminary positive results are used.
 
SUMMARY
 
Barbiturates are central nervous system depressants. They are used therapeutically as sedatives, hypnotics, and anticonvulsants. Barbiturates are almost always taken orally as capsules or tablets. The effects resemble those of intoxication with alcohol. Chronic use of Barbiturates leads to tolerance and physical dependence. Short acting Barbiturates taken at 400 mg/day for 2-3 months produce a clinically significant degree of physical dependence. Withdrawal symptoms experienced during periods of drug abstinence can be severe enough to cause death. Only a small amount (less than 5%) of most Barbiturates are excreted unaltered in the urine. The detection period for the Barbiturates in the urine is 4-7 days.
 
The BAR Rapid Test Cassette (Urine) is a rapid urine-screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Barbiturates in urine. The BAR Rapid Test Cassette (Urine) yields a positive result when the Barbiturates in urine exceeds the cut-off level.
 
PRINCIPLE
 
The BAR Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs that may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.
 
During testing, a urine specimen migrates upward by capillary action. Barbiturates, if present in the urine specimen below the cut-off level, will not saturate the binding sites of the antibody in the test. The antibody coated particles will then be captured by immobilized Barbiturate-protein conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Barbiturate level exceeds the cut-off level because it will saturate all the binding sites of anti-Barbiturate antibodies.
 
A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
 
REAGENTS
 
The test contains mouse monoclonal anti-Barbiturates antibody coupled particles and Barbiturates-protein conjugate. A goat antibody is employed in the control line system.
 
DIRECTIONS FOR USE
 
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
 
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
 
2. Place the test device on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120 uL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.

 

Barbiturates BAR Rapid Test Cassette Urine 200ng/ml GC / MS 0

3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
 
INTERPRETATION OF RESULTS
 
(Please refer to the illustration above)
 
NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the Barbiturate concentration is below the detectable cut-off level.
 
*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.
 
POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the Barbiturate concentration exceeds the detectable cut-off level.
 
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
 
QUALITY CONTROL
 
A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique. Control standards are not supplied with this kit; however, it is recommended that positive and negative controls be tested as good laboratory testing practice to confirm the test procedure and to verify proper test performance.
 
Order Information
 
Cat. No. Product Specimen Pack
DBA-102 Barbiturate (BAR) Rapid Test Cassette Urine 40T
DBA-114 Barbiturate (BAR) Rapid Test Panel Urine 40 T
DBA-101 Barbiturate (BAR) Rapid Test Dipstick Urine 50 T
DBA-802 Barbiturates (BAR) Rapid Test Cassette Oral Fluid 25 T
DBA-803 Barbiturates (BAR) Rapid Test Device Oral Fluid 25 T
DBA-402 Barbiturates (BAR) Rapid Test Cassette WB/S/P 40 T
DBA-X14 Barbiturate (BAR) Rapid Test Panel Powder 25 T
DBA-H902 Barbiturate (BAR) Rapid Test Cassette Hair 10 T